Icee Fishing app icon Android · Watch regulation log

Icee Fishing: log every regulation session, down to the second per day

Record timing readings, adjustments and results for each movement. Compare delta, rate, amplitude and beat error against your targets, position by position.

Download Icee Fishing
  • 6 radar positions
  • 4 timing metrics
  • 3 target checks per job

A reading you did not log is a reading you cannot compare next session.

Starting points

Choose a regulation preset to copy

Three reference profiles taken from the screens of Icee Fishing. Select one, copy its code into your notes, then open the app and build the record.

Selected Calibre reference

ETA 2824-2 profile

The first entry in the ETA group of the calibre list.

ETA2824-28800-L50-J25
  • Beat rate 28800 bph
  • Lift angle 50°, 25 jewels
  • Sibling entries: ETA 2836-2, ETA 2892-A2
Download Icee Fishing
Selected Movement record

Seiko NH35 dive build

The example record shown in the app: Turtle diver build.

NH35-21600-L53-J24
  • Beat rate 21600 bph
  • Lift angle 53°, 24 jewels
  • Stores serial number and date added
Download Icee Fishing
Most useful Selected Job targets

Delta 15.0 target set

The three target checks that decide when a job can close.

Open job example: delta 18.8 s/d against a 15.0 s/d target. 3.8 s/d left to remove.
D15.0-R0.0/+5.0-BE0.5
  • Delta 15.0 s/d or less
  • Rate 0.0 to +5.0 s/d
  • Beat error 0.5 ms or less
Download Icee Fishing

These codes are reference notes built from values visible in the app screens. They are not promo codes and unlock no rewards. Check the Google Play listing for pricing.

Under the case back

Inside the regulation workflow

Icee Fishing is organised around one object: the movement record. You pick a base calibre from the reference list or add your own. The list groups ETA (2824-2, 2836-2, 2892-A2), ETA Valjoux (7750) and Miyota (Citizen), and each row shows beat rate in bph, lift angle and jewel count. The record then stores a name, base calibre, serial number, date added and a target status.

Regulation happens in jobs. A job holds targets, for example delta of 15.0 s/d or less, rate between 0.0 and +5.0 s/d, and beat error of 0.5 ms or less. Three progress bars track the latest delta, latest average rate and latest maximum beat error. Status is written out in words such as "Not yet", so it never depends on colour alone.

Each session captures what the timing machine shows: rate, amplitude and beat error across six positions, DU, DD, CU, CD, CL and CR. The position radar plots them around a zero ring with a ±20 scale tag. Outside the ring is fast, inside is slow, and one tap flips between the current and previous session. Logged adjustments feed a change-and-effect timeline that measures how far each tweak moved the delta from the baseline.

Verified specifications

App nameIcee Fishing
Package IDcom.tisoot.ukul
PlatformAndroid (Google Play)
Store descriptionTrack watch regulation: log timing readings, adjustments and results
Reference calibresETA 2824-2, ETA 2836-2, ETA 2892-A2, Valjoux 7750, Miyota (Citizen) group
Spec fields per calibreBeat rate (bph), lift angle, jewels
Session metricsDelta s/d, average rate s/d, amplitude, beat error
Radar positionsDU, DD, CU, CD, CL, CR
NavigationFour-tab bottom bar, Calibres tab included
Version, size, ratingNot shown in the store material used for this page
On the bench

Bench tools, itemised

01

Calibre reference

Browse common movements grouped by manufacturer. Every row lists bph, lift angle and jewels, so you check the spec before you open the case.

02

Search and custom calibres

Search by calibre or manufacturer. Missing your movement? Add a custom calibre and keep it next to the reference entries.

03

Movement records

One record per watch: name, base calibre, serial number, date added and a target status. Open the current job, view history, edit or delete.

04

Six-position radar

See rate by position at a glance. The orange polygon is this session and the lavender one is the previous. Worst position is highlighted in the chips.

05

Targets with progress bars

Delta, average rate and maximum beat error each get a bar with a target marker. Log adjustment, record session or close the job from the same screen.

06

Change and effect timeline

Starts at the baseline. Arrow length shows how far each adjustment moved the delta. Tap a session to expand its readings table.

Workflow

From baseline to closed job

Opening a job

  • Pick the movement. Choose a calibre from the list or add a custom one.
  • Create the record. Name the build, enter the serial number and confirm bph, lift angle and jewels.
  • Set the targets. Delta, rate window and maximum beat error define what "done" means.
  • Record the baseline. The first session becomes the reference every adjustment is measured against.

Reading a session

  • Metric chips. Delta s/d, average rate s/d, amplitude and beat error, with the worst position called out.
  • Radar. Vertices outside the zero ring run fast, inside run slow.
  • Readings table. Rate, amplitude and beat error for each position.

Closing the loop

  • Log adjustment after each change on the regulator.
  • Record session to measure what the change did.
  • Watch the bars. Each shows its target marker and a written status.
  • Close job when the targets are met, or delete it if it was a false start.

Open your first regulation job in Icee Fishing

Android, via Google Play. Price and install size are listed on the store page. Pick a calibre, set the targets and log your baseline session.

Download Icee Fishing

Requirements, ads disclosure and age rating are not shown in the material this page is based on. Please confirm them on the Google Play listing.